Internationally Accredited Manufacturer’s Certificate

 

ISO 14001:2015

Environmental management systems

ISO 9001:2015

Quality management systems

CE Certification

FloorScore®

Indoor air quality (IAQ) certification


Internationally Accredited Test Report Result

 

Formaldehyde emission 

 Test method: EN 717-1

 Result: Result: 0.004 mg/m³ (Complies with E1 formaldehyde emission standard ≤ 0.124 mg/m³)


 Sum VOC emission 

 Test method: DIBt / AgBB 2021 SVOC Emission Testing at 3 Days vs. 28 Days

 Result: Pass


 Pentachlorophenol (PCP) 

 Test method: FD CEN/TR 14823:2006

Result: ND (Not detected – no PCP was found in the sample, confirming compliance)


 Total lead in substrate materials and Soluble heavy metal in substrate materials 

 Test method: ASTM F963-17

Result: ND (Not detected — no restricted substances were detected in the sample)


 Reaction to fire classification 

 Test method: EN 13501-1

Result: Bfl-s1 (Ensuring excellent flame resistance and low smoke emission)

 


 Castor chair test 

 Test method: ISO 4918:2016

 Result: No visible damage


 Dimensional stability and curling 

 Test method: ASTM F2199-20

 Result:

 Dimensional stability X: -0.01%, Y: -0.01% (excellent stable)

 Curling value: 0.50 mm (very slight – negligible)


 Static load (residual indentation) 

 Test method: ASTM F326-1-20 & ASTM F970-17

 Result: 0.09mm (very slight – negligible)


 Shod ramp test 

 Test method: DIN EN 16165:2023-02

 Result: Slip Resistance Class R10 (suitable for kitchens, corridors, and shops)


 Resistance to chemicals 

 Test method: ASTM 925-13(2020)

 Result: Rating 0 (no change)


 REACH (Test against 241 SVHC + 10 Potential SVHC) *SVHC stands for Substances of Very High Concern

 Test method: With reference to SGS In-House method, analysis was performed by ICP-OES, UV-VIS, GC-MS, HPLC-DAD/MS and Colorimetric Method

 Result: All substances less than 0.1% (Pass)